Page locationPage location : Home >  产品中心 >  Control Cable

RVV Flexible Wire (CU/PVC/PVC)

Release time:2021-05-15

Copper Core PVC Insulated PVC Sheathed Flexible Wire


product description:
The full name of RVV wire is copper core PVC insulated PVC sheathed flexible wire, also known as light PVC sheathed cord, commonly known as soft sheathed wire, which is a kind of sheathed wire. The rated voltage is 300V/500V, the number of cores ranges from 2 to 24 according to the national standard. Two or more cores are twisted into a cable, and the outer layer is twisted to the right. Mainly used in power lines, control lines and signal transmission lines for electrical appliances, meters, electronic equipment, and automation devices. Specifically, it can be used in anti-theft alarm systems, building intercom systems, etc.

Inspection requirements:
RVV refers to the multi-strand copper core flexible wire, the logo on the external line, the comparable thickness of the skin layer and the core. The skin layer is generally a polychloride material. The copper core is 19 strands. The specifications are generally 1, 1.5, 2.5 square millimeters .Look at the length of the line (a circle is 100 meters), the national standard line is 95-100 meters, and the non-standard line is about 90 meters.

Product performance:
Product name: RVV cable, RVV wire and cable
Rated voltage: 300V/500V.
Conductor: Multi-stranded copper conductor, in line with GB/T 3956 category 5 (equivalent to IEC60228.5).
Insulation: Polyvinyl chloride compound (PVC).
Sheath: flexible polyvinyl chloride compound (PVC), gray (RAL7001).
Core identification: ≤5 cores, colored cores; black cores, white numbers, yellow and green ground wires.
Number of cores: 2-5 cores, 7-36 cores (products out of the CCC catalog, no CCC certification).
Cross-sectional area: 0.75-2.5mm², 0.5, 2.5-35mm² (products out of the CCC catalog, no CCC certification).
Test voltage: 2000V, 5min.
Insulation resistance: >200M ohm×KM.
Operating temperature: -30~ +70℃.
Bending radius: 15× outer diameter of cable.
Flame retardant properties: IEC 60 332.1.
Reference standards: GB 5023, IEC60227, HD VDE21.5 S3.
Packing specifications: 100m, 500m, 1000m.

Application:
RVV cable is mainly used in flexible use places such as medium and light mobile electrical appliances, instrumentation, household appliances, power lighting, etc., can transmit control signals, can also transmit power signals, and is also suitable for laying in bridges and hoses. At the same time, this product has obtained the CCC and CE mark certification, and meets the requirements of HD (EU harmonized standards). It can be applied not only to the Chinese market, but also to the European market. According to the HD standard, the cable model is H05VV-F.

Specification wire core number:
2×0.50, 3×0.50, 4×0.50, 5×0.50, 6×0.50, 7×0.50, 8×0.50, 10×0.50, 12×0.50, 18×0.50, 25×0.50, 36×0.50.
2×0.75, 3×0.75, 4×0.75, 5×0.75, 6×0.75, 7×0.75, 8×0.75, 10×0.75, 12×0.75, 18×0.75, 25×0.75, 36×0.75.
2×1.0, 3×1.0, 4×1.0, 5×1.0, 6×1.0, 7×1.0, 8×1.0, 10×1.0, 12×1.0, 18×1.0, 25×1.0, 36×1.0.
2×1.5, 3×1.5, 4×1.5, 5×1.5, 6×1.5, 7×1.5, 8×1.5, 10×1.5, 12×1.5, 18×1.5, 25×1.5, 36×1.5.
2×2.5, 3×2.5, 4×2.5, 5×2.5, 6×2.5, 7×2.5, 8×2.5, 10×2.5, 12×2.5, 18×2.5, 25×2.5, 36×2.5.
2×4.0, 3×4.0, 4×4.0, 5×4.0, 7×4.0.
2×6.0, 3×6.0, 4×6.0, 5×6.0, 7×6.0.
2×10.0, 3×10.0, 4×10.0, 5×10.0.
3×16.0, 4×16.0, 5×16.0.
4×25.0, 5×25.0.
4×36.0, 5×36.0.
Notes:
①There is also a larger rated voltage 450/750V, 600/1000V RVV cable.
②There are more core wire colors.
③Other special places use RVV cable products (high and low temperature resistance, corrosion resistance, cutting resistance, etc.).
④The product model outside the CCC catalog is RVV, without CCC certification.




Key points for indoor laying of flame-retardant control cables:
1. Non-armoured cables should be laid indoors. When laying horizontally, the distance between the cable and the ground should not be less than 2.5m. When laying straight, the distance between the cable and the ground should not be less than 1.8m. When the above requirements cannot be met, measures should be taken to avoid mechanical damage to the cables; when exposed to special rooms such as power distribution rooms, motor rooms, equipment floors, etc., this restriction is not imposed.
2. When cables with the same voltage are laid in parallel, the cable net distance shall not be less than 35mm, and not less than the outer diameter of the cable; it is not subject to this restriction when laying in bridges, bridges, and trunking. Power cables and control cables of 1kV and below should be laid separately from power cables of 1kV and above. When used side by side, the clear distance should not be less than 150mm.
3. The clear distance between the overhead bare cable and the heat pipe is not less than 1m; when the clear distance is less than or equal to 1m, heat preservation measures should be taken. The net distance to the non-thermal pipeline should not be less than 0.5m. When the clear distance is less than or equal to 0.5m, measures should be taken to avoid mechanical damage to the cable section close to the pipeline and the cable section extending 0.5m from both ends of the section.